A-100LMB is the low cost version of the A-100PMB. This version is with black coating: A-100LMBV.
Dimensions and weight:
outside dimensions: ~ 87 (length) x 19 (height) x 38 (depth) cm
weight of the case (incl. bus boards, power supplies, without modules): ~ ? kg
available 19" width and height: 2 x 3U x 168 HP
Quantity of bus boards: 4
Maximum Output Current:
two built-in A-100PSU3 : +12V/4000 mA, -12V/2400mA, +5V/8000mA
Assignment of the power supplies to the bus boards:
A-100PSU #1: bus board pair left
A-100PSU #2: bus board pair right
Each power supply A-100PSU3 delivers max. +12V/2000 mA, -12V/1200mA, +5V/4000mA
Usable depth for modules:
approx. 65 mm in the lower front row
approx. 90 mm in the upper angled row
(measured from inner side of the front panel until end of the pc board of the module)
Position of the mains inlet: center of the rear panel
All bus boards are located in the rear area (even those for the modules that are mounted in the front row). This was necessary to take advantage of the full height of the front area for installation of modules. The max. depth for modules in the front row is ~ 65 mm.
Dimensions and weight:
outside dimensions: ~ 87 (length) x 19 (height) x 38 (depth) cm
weight of the case (incl. bus boards, power supplies, without modules): ~ ? kg
available 19" width and height: 2 x 3U x 168 HP
Quantity o
Product Overview
A-100LMB is the low cost version of the A-100PMB. This version is with black coating: A-100LMBV.
Dimensions and weight:
outside dimensions: ~ 87 (length) x 19 (height) x 38 (depth) cm
weight of the case (incl. bus boards, power supplies, without modules): ~ ? kg
available 19" width and height: 2 x 3U x 168 HP
Quantity of bus boards: 4
Maximum Output Current:
two built-in A-100PSU3 : +12V/4000 mA, -12V/2400mA, +5V/8000mA
Assignment of the power supplies to the bus boards:
A-100PSU #1: bus board pair left
A-100PSU #2: bus board pair right
Each power supply A-100PSU3 delivers max. +12V/2000 mA, -12V/1200mA, +5V/4000mA
Usable depth for modules:
approx. 65 mm in the lower front row
approx. 90 mm in the upper angled row
(measured from inner side of the front panel until end of the pc board of the module)
Position of the mains inlet: center of the rear panel
All bus boards are located in the rear area (even those for the modules that are mounted in the front row). This was necessary to take advantage of the full height of the front area for installation of modules. The max. depth for modules in the front row is ~ 65 mm.