This new module should not be judged by it’s size, at 6hp it’s packed with features.
At its core it features a noise source and two precision Sample & Holds with 0.01% of maximum deviation from the Input which allows for quantized signals to be sent through without any noticeable detuning or the typical voltage drops over time.
The Sample & Hold sections can also be used as a Track & Hold meaning it holds the incoming input while the Trigger input is ON and lets the input flow to the output when the Trigger input is OFF.
Each section also features it’s own slew processor with a single control over attack and decay and an ON/OFF switch.
The noise signal is normalled to both sections inputs, meaning that without a jack plugged into the Input the sample and hold function will act upon the incoming noise signal generating random CV values.
The [Trigger A Alternate] switch allows to Link both sections so that any trigger input in Trigger A will alternate between triggering the A and B section.
Besides each section outputs there’s also 4 extra outputs: Noise, Difference, Average and Sum. The [Noise] output is coming from the noise source, the [Difference] output is the subtraction of section A minus section B, the [Average] output is the sum of both A plus B and then divided by 2 and finally the [Sum] output is the sum of both A plus B sections.
Product Overview
This new module should not be judged by it’s size, at 6hp it’s packed with features.
At its core it features a noise source and two precision Sample & Holds with 0.01% of maximum deviation from the Input which allows for quantized signals to be sent through without any noticeable detuning or the typical voltage drops over time.
The Sample & Hold sections can also be used as a Track & Hold meaning it holds the incoming input while the Trigger input is ON and lets the input flow to the output when the Trigger input is OFF.
Each section also features it’s own slew processor with a single control over attack and decay and an ON/OFF switch.
The noise signal is normalled to both sections inputs, meaning that without a jack plugged into the Input the sample and hold function will act upon the incoming noise signal generating random CV values.
The [Trigger A Alternate] switch allows to Link both sections so that any trigger input in Trigger A will alternate between triggering the A and B section.
Besides each section outputs there’s also 4 extra outputs: Noise, Difference, Average and Sum. The [Noise] output is coming from the noise source, the [Difference] output is the subtraction of section A minus section B, the [Average] output is the sum of both A plus B and then divided by 2 and finally the [Sum] output is the sum of both A plus B sections.